1 votes 1 votes Ans given is 6. Digital Logic digital-logic + – vaishali jhalani asked Jan 10, 2017 vaishali jhalani 391 views answer comment Share Follow See all 0 reply Please log in or register to add a comment.
4 votes 4 votes Q0 Q1 Q2 Q3 0 0 0 1(initial) 1 0 0 1(1st clock cycle) 1 1 0 0(2nd clock cycle) 1 1 1 0(3rd clock cycle) 0 1 1 1(4th clock cycle) 0 0 1 1(5th clock cycle) 0 0 0 1(6th clock cycle) i think your confusion was due to order of Q3, Q2, Q1, Q0. yankur9 answered Jan 10, 2017 yankur9 comment Share Follow See all 2 Comments See all 2 2 Comments reply vaishali jhalani commented Jan 10, 2017 reply Follow Share initial value is 1000. i am getting this order 1000 1100 1110 0111 0011 0001 At the end of 5th cycle 0001 will appear.. what should we write 5 or 6??? 0 votes 0 votes yankur9 commented Jan 10, 2017 reply Follow Share in question Q3 value 1 , Q2 0 ...........respectively your order of output is not correct 3 votes 3 votes Please log in or register to add a comment.