1 votes 1 votes Q) Which statements are true and also give reason ? 1) Clock cycle time in johnson counter is equal to delay of one flip flop. 2) Clock cycle time in Ring counter is equal to (delay of one flip flop)*(no. of flip flops). Lone Wolf asked Aug 7, 2018 Lone Wolf 718 views answer comment Share Follow See all 9 Comments See all 9 9 Comments reply Show 6 previous comments Shaik Masthan commented Aug 7, 2018 reply Follow Share it's our wish and it's depend upon our requirement of output frequency, there is no rule that clock time period of ring counter and johnson counter should be same moreover, the output produces by the ring counter doesn't change depend upon CLK period, but width of that o/p pulse change depend upon CLK period 0 votes 0 votes BASANT KUMAR commented Aug 7, 2018 reply Follow Share @shaik masthan .if we keep situation same in both of the counter then clock time period will be same or not?? 0 votes 0 votes Shaik Masthan commented Aug 7, 2018 reply Follow Share keep situation same in both of the counter it means " output pulse width same " , if it is your requirement then yes...CLOCK periods must be same 1 votes 1 votes Please log in or register to add a comment.